SCADA IDS Signatures (SIS)

CRITIFENCE® SCADA IDS Signatures Database (SIS)

RealWin HMI Service Buffer Overflow 2

Date Title Author SVE-ID
2016-03-03RealWin HMI Service Buffer Overflow 2Digital Bond268076827
Description
This vulnerability_exploit rule contains IDS rule that detect exploit attempts on known control system vulnerabilities. The CVE, if available, and common name of the applicable vulnerability precedes each rule.

Signature

						
							
								
alert tcp any any -> any 912 (msg:"RealWin HMI Service Buffer Overflow Attempt 2";
 flow:established,to_server;
 content:"|64 12 54 6a 20 00 00 00|";
 depth:8;
 byte_test:4,>,739,0,little,relative;
 reference:cve, CVE-2010-4142;
 reference:url,digitalbond.com/tools/quickdraw/vulnerability-rules;
 sid:1111611;
 rev:1;
 priority:1;
)